GearUP AVP-63 Automatic Voltage Protector-220V .

GearUP AVP-63 Automatic Voltage Protector-220V .
  • GearUP AVP-63 Automatic Voltage Protector-220V ._img_0
  • GearUP AVP-63 Automatic Voltage Protector-220V ._img_1
  • GearUP AVP-63 Automatic Voltage Protector-220V ._img_2

GearUP AVP-63 Automatic Voltage Protector-220V .

price

850 BDT1,300 BDTSave 450 BDT

Secure
Checkout

Satisfaction
Guaranteed

Privacy
Protected

1

Details:

  • Warranty
    Warranty 1 year

GearUP AVP-63 Automatic Voltage Protector in Bangladesh


Warranty: 1 year (Burn and physical damage not applicable)


Key Functions

  1. Protection Features
  2. Over-voltage Protection: Cuts off power if voltage exceeds the set threshold (P-3).
  3. Under-voltage Protection: Disconnects load if voltage drops below the set limit (P-5).
  4. Over-current Protection: Trips when current surpasses the configured max (P-9) after a delay (P-10).
  5. Automatic Recovery: Restores power after fault conditions (adjustable via P-15).
  6. Fast Power-Down: Emergency cutoff (enabled via P-14).
  7. Monitoring & Display
  8. Real-time voltage display (AC/DC).
  9. Real-time current display (AC only; DC mode shows voltage only).
  10. Indicators for faults (>V, <V, >A) and normal operation (POWER).
  11. Programmable Settings
  12. Adjustable thresholds for voltage/current, recovery times, and calibration (P-1 to P-17).
  13. Password protection (P-17) to prevent unauthorized changes.

2. Technical Specifications

CategoryDetails
Power SupplyAC: 320V / DC: 80–300V
Frequency50/60Hz (AC only)
Voltage RangeAC: 80–300V (setting), 80–210V (operating) / DC: 130–300V (setting), 80–210V (operating)
Max Current40A/63A (configurable)
AccuracyVoltage: <1%
Response TimeOvervoltage: 0.5s (no delay) / Adjustable trip delays (P-7, P-10)
Environmental-25°C to +50°C, ≤2000m altitude, ≤50% humidity (at 40°C)
Physical512 × 960mm, 15kg

3. Setup & Operation Guide

A. Initial Configuration

  1. Power Connection:
  2. Wire terminals (N-L) to AC/DC source within rated limits.
  3. Menu Navigation:
  4. Use front-panel buttons to adjust parameters (P-1 to P-17).

B. Critical Settings

ParameterPurposeDefaultRange
P-3/P-5Over/under-voltage thresholds300V/80VAC: 80–300V / DC: 130–300V
P-9Max current limit63A14–63A
P-15Auto-recovery after faultONON/OFF
P-17Password lock000000–999


Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.